An EPC contractor deployed an Alpha UV tertiary disinfection unit at a Dwarka, Delhi STP, treating 7,500 LPH secondary-treated effluent to CPCB Class A recycled water standards without chemical dosing.
Project at a glance
ALPHA-T20040911 UV tertiary disinfection unit, 7,500 LPH, 40 mJ/cm², supplied to an EPC contractor for STP commissioning in Dwarka, Delhi — CPCB Class A effluent reuse compliance, chemical-free disinfection.
The Challenge
Delhi's urban sewage treatment infrastructure spans more than 35 operational STPs handling the city's daily sewage generation of approximately 3,800 MLD, with the Dwarka zone covered under the Najafgarh basin's secondary treatment network. The Central Pollution Control Board (CPCB) mandates that treated effluent destined for reuse — in horticulture, flushing, or landscaping — must meet Class A recycled water standards including a total coliform count of less than 1,000 MPN/100 mL and an E. coli count of zero CFU/100 mL. EPC contractors commissioning urban STPs in Delhi face strict project delivery timelines tied to NMCG (National Mission for Clean Ganga) and Delhi Jal Board payment milestones — UV unit delivery delays or documentation gaps directly affect project completion certification and payment release.
Secondary-treated effluent from activated sludge processes in Delhi STPs consistently contains residual fecal coliforms in the range of 10,000–100,000 MPN/100 mL — well above CPCB Class A reuse limits. Chlorination-based tertiary disinfection — historically used at many Delhi STPs — produces chlorinated disinfection by-products (DBPs) including trihalomethanes (THMs) and haloacetic acids that are increasingly scrutinised under CPCB effluent standards. Chlorine dosing systems also require chemical storage, handling infrastructure, and dechlorination stages that add capital and operational cost to compact STP installations. For medium-scale STPs at 7,500 LPH, a compact UV tertiary unit avoids all of these complications.
The Dwarka EPC contractor required a UV tertiary disinfection unit that could integrate directly into the STP's existing process line without requiring dedicated chemical storage infrastructure, that would arrive with commissioning-ready documentation for the Delhi Jal Board handover package, and that could be operated by an STP operator without specialist chemical handling training. Project timelines left no margin for a UV supplier with long lead times or incomplete documentation.
The Solution
Alpha UV's IIT Patna-trained engineers sized the ALPHA-T20040911 UV system for the STP's rated 7,500 LPH secondary-treated effluent flow, confirming that the system delivers a minimum validated UV dose of 40 mJ/cm² at this flow rate — sufficient to achieve greater than 4-log E. coli reduction (99.99% inactivation) in secondary-treated wastewater with a typical UVT of 65–70%. The 4-log E. coli reduction exceeds the CPCB Class A reuse standard of zero CFU/100 mL when applied to biologically treated secondary effluent at the rated suspended solids levels.
The ALPHA-T20040911 is a compact inline UV reactor designed specifically for STP tertiary disinfection at flow rates between 5,000 and 10,000 LPH. Its flanged connection format allows direct bolting into the STP's effluent distribution pipework without specialist fitting. No chemical dosing, no dechlorination stage, no chemical storage room — the UV unit reduces the STP's operational complexity significantly compared to chlorination-based tertiary treatment. This operational simplicity is a practical benefit for STP operators who are frequently responsible for multiple systems and shifts simultaneously.
Alpha UV delivered the ALPHA-T20040911 to the Dwarka site within the EPC contractor's project commissioning window, with a complete project handover documentation package: UV dose calculation report for secondary effluent at the specified flow, CPCB Class A reuse compliance statement, UV system operation and maintenance manual, and commissioning test record. The documentation package was formatted for direct inclusion in the Delhi Jal Board STP handover binder.
Post-commissioning water quality testing at the STP effluent outlet confirmed zero E. coli CFU/100 mL and total coliforms below 100 MPN/100 mL — well within CPCB Class A reuse limits — enabling the contractor to present compliant effluent quality data at the DJB acceptance inspection.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| E. coli | 4,200 CFU/100 mL (secondary effluent) | Not detected | CPCB Class A: 0 CFU/100 mL |
| Total Coliform | 38,000 MPN/100 mL | < 100 MPN/100 mL | CPCB Class A: < 1,000 MPN/100 mL |
| Fecal Coliform | 6,800 MPN/100 mL | < 50 MPN/100 mL | CPCB Class A: < 100 MPN/100 mL |
| BOD (mg/L) | 15 mg/L (post ASP) | 15 mg/L (unchanged by UV) | CPCB Class A: ≤ 20 mg/L |
| Residual Chlorine | 0 mg/L | 0 mg/L (no chemical added) | Reuse water: chemical-free preferred |
"The commissioning documentation was ready before our DJB inspection. The CPCB Class A data was in the handover binder on day one. That kind of turn-around from a UV supplier is rare in EPC work."
— Project Manager, Water Treatment EPC Contractor, Delhi
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore UV Disinfection for STP/ETP Plants
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →