A brewery in Nalbari, Assam required a high-flow UV system to eliminate chloramines from municipal process water, protecting yeast health and ensuring CIP rinse quality at 30,000 LPH.
Project at a glance
ALPHA-ED754550P UV system with 4 Philips 75W TUV UV-C lamps, 76mm Tri-Clamp, SS304 construction, delivering 60 mJ/cm² at 30,000 LPH for chloramine destruction in brewery process water — FSSAI HACCP CCP compliant.
The Challenge
India's brewing industry has expanded rapidly across non-traditional states, with Assam emerging as a significant producer serving the northeast's growing organised retail and hospitality markets. Commercial breweries in India — whether producing lager, wheat beer, or craft styles — operate under FSSAI licensing and are subject to HACCP-based quality management requirements that classify process water treatment as a Critical Control Point (CCP). With per-litre water consumption in brewing ranging from 4 to 8 litres of water per litre of beer produced, maintaining consistent process water quality is a direct production efficiency and product quality imperative. Nalbari's municipal water supply, like much of northeastern India's municipal infrastructure, relies on chloramine disinfection — a compound that standard treatment equipment struggles to fully address at scale.
Chloramines (combined chlorine compounds formed when chlorine reacts with ammonia in source water) pose a dual threat to breweries. When introduced into fermentation vessels, chloramines inhibit yeast propagation and cellular activity, producing off-flavours including medicinal and plastic-tasting chlorophenol compounds. Even at concentrations as low as 0.1 mg/L, chloramine-contaminated process water causes perceptible flavour defects that result in batch rejections at FSSAI quality checks and hospitality buyer tastings. CIP (Clean-in-Place) rinse circuits exposed to chloramines suffer similar issues — residual chloramine carryover into fermentation vessels after CIP is a persistent source of contamination that the Nalbari brewery was experiencing every monsoon season when municipal chloramine concentrations spiked.
Carbon filtration — the conventional remedy — requires regular media replacement, generates spent media waste, and cannot provide the HACCP-auditable CCP monitoring record that FSSAI inspectors expect. The brewery's existing carbon beds were showing breakthrough chloramine concentrations during peak seasonal demand, and the facility's quality team recognised that a carbon-only approach lacked both the reliability and the documentation capability needed for the upcoming FSSAI HACCP audit. A permanent, chemical-free, monitoring-capable solution at the brewery's water inlet was required.
The Solution
Alpha UV's IIT Patna-trained engineers conducted a brewery site assessment at Nalbari, reviewing the facility's water inlet specifications, peak process water demand, and CIP circuit requirements. The engineering team sized the ALPHA-ED754550P UV system for a maximum instantaneous flow of 30,000 LPH — the brewery's peak combined demand across brewing, CIP, and utilities — with the UV dose and lamp configuration calculated to achieve full chloramine photolysis at this flow rate even at the minimum expected water UVT of 98% for the municipal supply.
The ALPHA-ED754550P is configured with 4 × Philips 75W TUV UV-C lamps in a 76mm Tri-Clamp SS304 stainless steel chamber. At a UV dose of 60 mJ/cm², the system achieves the photolysis threshold required to break the N-Cl bond in both monochloramine and dichloramine — the two dominant forms found in municipal supply — without introducing any chemical residual. The 76mm Tri-Clamp end connections comply with EHEDG hygienic design standards for brewery process equipment, allowing the chamber to be incorporated into CIP circuits and cleaned-in-place alongside connected vessels and pipework. The SS304 electropolished interior prevents biofilm adhesion between CIP cycles.
The selection of 60 mJ/cm² — double the minimum drinking water disinfection dose — was specifically validated for the chloramine photolysis application, where effective N-Cl bond cleavage requires higher doses than simple microbial inactivation. The continuous UV intensity sensor output from the ALPHA-ED754550P feeds directly into the brewery's HACCP CCP monitoring record — the sensor provides a time-stamped data log that serves as the documented CCP performance evidence for FSSAI audits without requiring manual water testing at every shift.
Alpha UV supplied a complete FSSAI brewery compliance package: UV dose calculation report for the chloramine photolysis application, Philips TUV lamp COA, HACCP CCP monitoring protocol, SS304 material certificate, and a Tri-Clamp hygienic design compliance statement. The documentation enables the brewery's quality manager to present the UV system as a validated, monitored CCP in their FSSAI HACCP plan.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Monochloramine (NH2Cl) | 0.6 mg/L | < 0.02 mg/L | WHO brewing water: < 0.1 mg/L |
| Dichloramine (NHCl2) | 0.2 mg/L | Not detected | FSSAI brewery process water: 0 |
| Total Coliform | 8 CFU/100 mL | < 1 CFU/100 mL | FSSAI: 0 CFU/100 mL |
| Chlorophenol off-flavour | Detected (tasting panel) | Not detected | Internal brewery QC: 0 |
| CIP Rinse Chloramine | 0.3 mg/L | < 0.02 mg/L | Brewery CCP: 0 carryover |
"Chloramine off-flavours were costing us batch rejections every monsoon season. After the Alpha UV install, we haven't had a single complaint — and the FSSAI auditor accepted the UV sensor log as the CCP record."
— Head Brewer, Commercial Brewery, Assam
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Brewery UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageRelated Reading
Brewery UV Water Treatment — Chloramine Removal Case Study
Deep-dive technical article on this application from our engineering team.
Read the articleMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →