Quick Answer
The Alpha UV Pharmaceutical UV Disinfection System is a Philips UV-C system for pharmaceutical purified water and WFI loops — SS316L electropolished chamber, continuous 4–20 mA UV intensity monitoring, 500 to 50,000 LPH, with complete Revised Schedule M 2025 IQ/OQ/PQ documentation by IIT Patna engineers for CDSCO and WHO GMP audits.
Schedule M 2025 & WHO GMP compliant UV for pharmaceutical purified water and WFI
Pharmaceutical purified water and Water for Injection (WFI) are the most regulated water quality grades in Indian manufacturing — Revised Schedule M 2025 and WHO GMP require continuous UV dose monitoring, documented IQ/OQ/PQ validation, and SS316L wetted surfaces that meet 21 CFR Part 11 and CDSCO audit requirements. Alpha UV pharmaceutical-grade UV systems are engineered for purified water loop UV disinfection: the final microbiological kill step between purified water generation (RO + EDI) and point-of-use in formulation, filling, and packaging areas. SS316L electropolished chambers minimise biofilm risk in recirculating loops. Philips UV-C lamps with Certificate of Analysis are supplied with each system. IIT Patna engineers provide complete IQ/OQ/PQ documentation — including UV dose calculation, Philips lamp COA, SS316L material certificates, PLC commissioning report — structured for CDSCO, WHO PQ, and FDA audit submission. For WFI loops with sanitisation requirements, UV provides continuous bioburden control between periodic thermal or chemical sanitisation cycles.

Capacity
500 – 50,000 LPH

SS316L chamber · Philips UV-C lamp
Every Alpha UV System reactor geometry is validated through CFD simulation using ANSYS Fluent. The analysis below shows velocity streamlines and UV dose distribution across the reactor cross-section, confirming that minimum dose targets are met across the entire chamber volume — not just at the chamber centreline.
Turbulence Model
k-ε Realizable
Mesh Elements
~3.2 million cells
Convergence Criterion
Residuals < 10⁻⁴
Every Pharma UV ships with genuine Philips UV-C lamps. Not unbranded Chinese alternatives. Philips lamps are rated 9,000–12,000 hours — more than double the life of typical Chinese OEM lamps. A serial number certificate of authenticity is included with every lamp.
Lamp Life
9,000 – 12,000 hrs
UV Output Consistency
±5% over lifetime
Certification
CE · RoHS · NSF
Complete Schedule M 2025 IQ/OQ/PQ pack: UV dose calculation report, Philips UV-C lamp Certificate of Analysis, SS316L material test certificates, PLC control panel commissioning documentation, and IQ/OQ/PQ protocol templates — prepared by IIT Patna engineers and structured for CDSCO and WHO PQ audit submission.
Yes. Revised Schedule M 2025 requires continuous UV dose monitoring with alarm for pharmaceutical purified water and WFI UV systems. Alpha UV pharma systems provide a continuous 4–20 mA UV intensity output with configurable low-UV alarm relay — satisfying this requirement and providing the data log for audits.
40 mJ/cm² achieves 4-log bioburden reduction in purified water loops — the standard used in ISPE Baseline Vol. 4 for in-line UV between storage tank and point-of-use. For WFI loops with higher bioburden targets or for systems validated to USP <1231>, doses of 60–100 mJ/cm² are used.
UV provides continuous bioburden control in WFI recirculation loops between thermal or chemical sanitisation cycles — it suppresses microbial regrowth but does not replace periodic sanitisation. For WFI systems validated to pharmacopoeial standards, UV is the in-line polishing step, not the primary sanitisation method.
Explore the specific applications this system is engineered for.
Get a Quote
Share your flow rate and application — we'll respond with a UV dose calculation report and quote within 2 hours.
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
Send us your flow rate and application on WhatsApp — IIT Patna engineers respond in 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →