A biofuels production plant at Shahpura, Jabalpur, Madhya Pradesh installed a 35,000 LPH Alpha UV system at the WTP inlet, ensuring microbiologically clean water for biofuel production — delivered within 1 week of order confirmation.
Project at a glance
35,000 LPH UV system (HSN 84212110), 40 mJ/cm², Philips TUV UV-C, SS304, supplied to biofuels plant WTP inlet at Shahpura, Jabalpur, MP — 1-week delivery, protecting bioconversion and heat exchanger circuits.
The Challenge
India's biofuels sector has expanded rapidly under the National Biofuels Policy 2018 and subsequent 2022 amendments, with Madhya Pradesh emerging as a key production state for bioethanol from B-heavy molasses, sugarcane juice, and grain feedstocks under the Ethanol Blending Programme (EBP). Biofuels plants in MP's agricultural belt — including the Shahpura area near Jabalpur — require consistent, large-volume water inputs for fermentation substrate preparation, cooling circuits, and boiler feed, with water quality directly affecting production efficiency and equipment reliability. Jabalpur's surface water and groundwater sources carry variable microbial loads — particularly post-monsoon — that must be addressed at the WTP inlet before water enters any biological or thermal process circuit.
Biofuels production at the scale of a commercial ethanol plant involves multiple water-sensitive process areas: yeast propagation vessels require water free of competing wild-strain bacteria; heat exchangers in fermentation cooling circuits are vulnerable to biofilm-induced fouling that reduces heat transfer efficiency; boiler feed water requires microbiologically clean supply to prevent corrosion and scaling from biologically mediated deposits. At 35 m³/hr, the facility's WTP inlet flow represents a substantial treatment challenge — a UV system must be correctly sized for this flow rate to maintain the minimum 40 mJ/cm² dose at peak demand without flow-related dose shortfall.
The Shahpura plant's commissioning schedule created an urgent delivery requirement: the biofuels plant was completing civil construction and mechanical installation, and the WTP UV system was on the critical path for plant start-up commissioning. Any supplier unable to deliver within one week would delay the entire plant commissioning timeline, with direct financial consequences tied to the facility's EBP production quota allocation period. Standard industrial UV suppliers with 2–3 week manufacturing lead times could not meet this requirement.
The Solution
Alpha UV's IIT Patna-trained engineers received the Shahpura plant's WTP specifications and sized a 35,000 LPH UV water treatment system (HSN 84212110) for the biofuels plant's WTP inlet on the same day as enquiry. The engineering team confirmed the system specification — Philips TUV UV-C lamps in a heavy-gauge SS304 reactor — delivers a minimum validated UV dose of 40 mJ/cm² at the full 35,000 LPH rated flow with the facility's groundwater UVT of 93% (post-sand filtration), achieving 4-log E. coli reduction and adequate yeast wild-strain inactivation for fermentation circuit protection.
Alpha UV's manufacturing team prioritised the Shahpura order, completing fabrication, quality inspection, and dispatch within 1 week of order confirmation. The UV system was manufactured using in-stock Philips TUV UV-C lamps and SS304 reactor components maintained in Alpha UV's production inventory — the in-stock component strategy is specifically designed to support urgent industrial commissioning requirements. The 35,000 LPH system was delivered to the Shahpura plant site on day 7 post-order, meeting the plant's critical commissioning timeline.
WTP inlet placement was confirmed by Alpha UV's engineering team as the optimal installation point: treating all plant water supply upstream of distribution ensures that cooling circuits, fermentation support water, and boiler feed are all microbiologically protected from the first point of entry, without requiring separate UV units at each process area. The SS304 construction and 40 mJ/cm² dose are specified for continuous 24/7 operation at biofuels plant duty cycles, with Philips TUV lamp life adequate for 12-month operation between planned maintenance shutdowns.
Alpha UV delivered a complete documentation package at commissioning: UV dose calculation report for the 35,000 LPH biofuels plant application, Philips TUV lamp COA, SS304 material certificate, HSN 84212110 classification documentation for GST compliance, and an O&M manual referencing the plant's specific WTP configuration.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Total Coliform (WTP inlet) | 1,200 CFU/100 mL (post-monsoon groundwater) | Not detected | Biofuels plant process water: 0 |
| E. coli | 180 CFU/100 mL | Not detected | Fermentation protection: 0 |
| Wild yeast/mould | Detected (periodic post-monsoon) | Not detected | Fermentation protection: 0 |
| Aerobic plate count | 840 CFU/mL | < 10 CFU/mL | Biofuels process: < 50 CFU/mL |
| Heat exchanger biofilm indicator | Elevated (pre-UV) | Baseline reduced | Plant reliability: biofilm-free |
"One week from order to delivery at a 35 m³/hr spec — that is the kind of response that matters when a biofuels plant commissioning schedule is on the line. The WTP was running within 48 hours of delivery."
— Plant Commissioning Manager, Biofuels Plant, Madhya Pradesh
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Industrial UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →