A food processing plant in Ghaziabad, Uttar Pradesh deployed the Alpha UV ALPHA-ED4012532P system to achieve FSSAI-compliant process water disinfection across its production line, eliminating coliform contamination without chemical disinfectants.
Project at a glance
ALPHA-ED4012532P UV system, 40 mJ/cm², Philips TUV UV-C, SS304 construction, inline installation — FSSAI process water compliance at a food processing facility in Ghaziabad, Uttar Pradesh.
The Challenge
Ghaziabad's Loni and Sahibabad industrial corridors host a dense cluster of food and beverage processing facilities serving Delhi's massive consumer market. Food processors in this corridor operate under FSSAI FoSCOS licensing with annual inspection cycles that have become increasingly rigorous following the FSSAI's strengthening of water quality audit procedures under the 2023 Food Safety Standards (Licensing and Registration) regulations amendment. Municipal water supply in Ghaziabad — particularly during the monsoon season from July to September — shows elevated total coliform counts of 20–90 CFU/100 mL at industrial supply points due to distribution network ingress, well above the FSSAI process water standard of zero CFU/100 mL for food-contact applications.
Mid-scale food processors in Ghaziabad face a structural challenge: they lack the dedicated water quality management staff of larger food companies, so the UV system they install must be simple to operate, generate self-contained compliance documentation, and not require specialist laboratory testing to verify compliance between FSSAI inspections. For facilities producing packaged foods, snacks, or beverages, the FSSAI inspector's first question at a water quality audit is whether the facility has a validated microbial kill step documented at the terminal point before water enters the production process — a standard carbon filter or UV system without a dose certificate does not satisfy this requirement.
The Ghaziabad facility had been using chlorine dosing for process water disinfection but was accumulating complaints from its quality team about chlorine smell in products and difficulty maintaining consistent dosing during power fluctuations. The chlorine dosing system also required monthly chemical deliveries, storage compliance, and handling records that added operational overhead to a facility that preferred a fit-and-forget disinfection solution with FSSAI-compliant documentation.
The Solution
Alpha UV's IIT Patna-trained engineers sized the ALPHA-ED4012532P UV system for the Ghaziabad facility's production line process water flow, confirming the system delivers a minimum UV dose of 40 mJ/cm² at the rated flow with the facility's post-filtration water UVT of 96%. At 40 mJ/cm², the system achieves greater than 4-log E. coli reduction — the standard FSSAI requires for food-contact process water — without introducing any chemical residual that could affect product flavour, packaging integrity, or export market acceptability.
The ALPHA-ED4012532P is an inline SS304 stainless steel UV reactor with Philips TUV UV-C lamps in the medium-pressure range, configured for the compact flow requirements of a mid-scale food processing line. The inline installation format allowed the engineering team to insert the unit directly into the facility's existing process water pipework between the carbon filter outlet and the production line inlet — no civil works, no additional pumping, no chemical storage infrastructure required. The facility's chlorine dosing system was decommissioned following UV commissioning, eliminating the chemical delivery, handling, and disposal compliance burden entirely.
Alpha UV calibrated the UV intensity alarm to 90% of rated output — giving the facility manager advance notice before dose drops below the FSSAI CCP critical limit. The alarm is routed to the facility's existing plant control panel, integrating UV system monitoring into the facility's standard operator rounds without requiring a separate monitoring station.
A complete FSSAI food-contact water documentation package was delivered at commissioning: UV dose calculation report, Philips TUV lamp COA, SS304 material certificate, FSSAI process water compliance statement, and an FSSAI-formatted HACCP CCP record template. The documentation enables the facility to present the UV system as a validated, monitored CCP at FSSAI inspections without requiring specialist water quality expertise.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Total Coliform (monsoon peak) | 72 CFU/100 mL | Not detected | FSSAI: 0 CFU/100 mL |
| E. coli | 14 CFU/100 mL | Not detected | FSSAI: 0 CFU/100 mL |
| Residual Chlorine (from prior dosing) | 0.6 mg/L | 0 mg/L (eliminated) | Food process water: chemical-free preferred |
| Fecal Coliform | 22 CFU/100 mL | Not detected | FSSAI: 0 CFU/100 mL |
"FSSAI inspection came 3 months after installation. The inspector saw the UV dose certificate and CCP record — moved straight on. The chlorine smell in products is gone completely."
— Production Manager, Food Processing Plant, Uttar Pradesh
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Food Industry UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies