A fresh produce processing operation in Sehore, Madhya Pradesh deployed two Alpha UV systems with control panel for FSSAI-compliant wash water disinfection across dual processing lines, eliminating E. coli and Salmonella without chemical residue.
Project at a glance
2 × ALPHA-T20040910 UV systems with central control panel, 1-inch connection, 40 mJ/cm², FSSAI-compliant dual-stream wash water disinfection — Sehore, Madhya Pradesh fresh produce processing facility.
The Challenge
Madhya Pradesh is India's largest state by area and a major agricultural producer, with fresh produce processing facilities concentrated around Bhopal, Indore, and the Sehore district's growing food park cluster. Fresh produce processing in India — covering vegetables, fruits, and leafy greens — operates under FSSAI FoSCOS licensing with specific water quality requirements for produce washing and blanching water used in food-contact applications. The sector faces mounting pressure from modern trade retail buyers (supermarket chains, quick commerce platforms) who demand FSSAI compliance documentation and third-party water quality audit reports as supplier qualification requirements.
Fresh produce processing facilities use recirculating wash water that rapidly accumulates surface pathogens from soil, handling, and cross-contamination between produce batches. E. coli O157:H7, Salmonella enterica, and Listeria monocytogenes are the primary organisms of concern in Indian produce washing operations — all three are capable of causing serious foodborne illness and triggering product recalls that can be commercially catastrophic for small and mid-scale processors. Chemical sanitisers — primarily chlorine-based — have been widely used in India's produce washing sector but leave detectable residues that affect shelf life, produce flavour profiles, and are restricted under some export market standards. Ozone and UV provide chemical-residue-free alternatives.
The Sehore facility operates two separate processing lines for different produce categories — requiring simultaneous, independent disinfection of two water streams. The plant manager required a dual-system UV solution with centralised operator control, the ability to monitor both systems from a single panel without sending an operator to two separate locations, and a system format compatible with the facility's existing 1-inch process water pipework. No major pipework modification was acceptable within the project budget and timeline.
The Solution
Alpha UV supplied two ALPHA-T20040910 UV systems paired with a central dual-unit control panel to manage both systems from a single operator interface. The engineering team reviewed the Sehore facility's wash line flow rates and confirmed that the ALPHA-T20040910's 1-inch connection format matched the existing process water pipework — allowing direct inline installation without pipework modification or additional fittings.
Each ALPHA-T20040910 unit delivers a minimum UV dose of 40 mJ/cm² at the rated wash line flow, achieving greater than 4-log reduction of E. coli, Salmonella, and Listeria in wash water with the facility's UVT of 96% (post-sand filtration). The 40 mJ/cm² dose eliminates these pathogens without introducing chlorine, ozone, or any chemical residue that would affect produce quality or export market acceptability. The dual-system configuration ensures that each processing line receives validated independent disinfection — a line-1 failure does not compromise line-2, and the control panel displays the operational status of both units simultaneously.
The central control panel includes individual UV intensity indicators for both units, an audible alarm for each unit's low-intensity fault condition, and manual on/off switches for each system — simple enough for produce line operators to manage without specialist training. Alpha UV configured the alarm setpoint at 90% of rated UV intensity, providing an advance warning margin before the dose falls below the minimum CCP critical limit.
Alpha UV delivered a complete FSSAI food-contact water compliance package for the dual-system installation: UV dose calculation reports for each unit, FSSAI process water compliance statement, HACCP CCP protocol for the dual-stream wash water disinfection stage, and an operation and maintenance manual formatted for FSSAI audit files.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| E. coli (wash water) | 620 CFU/100 mL | Not detected | FSSAI food-contact: 0 CFU/100 mL |
| Salmonella spp. | Detected | Not detected | FSSAI: absent |
| Listeria monocytogenes | Detected (seasonal) | Not detected | FSSAI: absent |
| Total Coliform | 2,400 CFU/100 mL | < 10 CFU/100 mL | FSSAI: 0 CFU/100 mL |
"FSSAI inspection came 3 months after installation. The inspector saw the dual UV dose certificates and the control panel alarm records — moved straight on. No questions."
— Production Manager, Fresh Produce Processing Plant, Madhya Pradesh
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Food Industry UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies