An Alpha UV authorised dealer at Waluj MIDC, Aurangabad, Maharashtra procured the heavy-duty ALPHASD756576P 4-inch flange UV system for OEM supply to industrial water treatment projects in the Marathwada manufacturing belt.
Project at a glance
ALPHASD756576P 4-inch flange industrial UV system, SS304 heavy-duty, Philips TUV UV-C, supplied to an authorised dealer at Waluj MIDC, Aurangabad — Maharashtra industrial OEM distribution, IGST-compliant.
The Challenge
Aurangabad (officially renamed Chhatrapati Sambhajinagar) hosts one of Maharashtra's most significant industrial clusters in the Waluj and Chikalthana MIDC zones, with an automotive-dominant manufacturing base that includes major two-wheeler OEMs, automotive component manufacturers, and engineering companies. The Marathwada manufacturing region generates substantial demand for industrial water treatment — from cooling tower makeup water treatment to CED coating bath water purification and ETP effluent reuse — served by a network of local OEM dealers and system integrators who build complete water treatment packages around industrial UV systems as the terminal disinfection stage.
Industrial water treatment OEMs and system integrators in Maharashtra's Marathwada belt require UV disinfection units with large-bore connections suitable for high-flow industrial applications. The 4-inch flange format is a standard connection specification for industrial process water flows above 20,000 LPH — the range typical of automotive plant cooling circuit and ETP effluent streams. Standard small-bore threaded UV units are inadequate for these applications; they create velocity-related UV dose shortfall when forced to handle high flows, and their pressure ratings are insufficient for industrial system operating pressures.
Dealers at MIDC industrial zones also require technically complete documentation that they can pass through to their industrial clients — including UV dose certificates, material specifications, and compliance statements compatible with IATF 16949, ISO 14001, and CPCB regulatory requirements. OEM dealers who source UV systems from non-manufacturer suppliers often receive equipment without documentation, forcing them to carry the compliance liability when their industrial client's audit team asks for performance evidence. IGST-compliant inter-state supply documentation is a non-negotiable procurement requirement for MIDC dealers managing GST accounts across Maharashtra.
The Solution
Alpha UV supplied the ALPHASD756576P UV system with 4-inch flange connections to the Waluj MIDC dealer — a heavy-duty SD-series industrial UV reactor suitable for the dealer's industrial customer base across Aurangabad's automotive, engineering, and manufacturing sectors. The 4-inch flange format enables direct integration into large-bore industrial pipework at high flow rates (above 20,000 LPH) without restriction or pressure loss, maintaining consistent UV dose delivery at the system's rated flow capacity.
Alpha UV's IIT Patna-trained engineers confirmed the ALPHASD756576P's UV dose rating and industrial duty cycle suitability for the dealer's application range — cooling water treatment, ETP reuse disinfection, and process water inlet treatment. The SD-series construction (heavy-gauge SS304 reactor, industrial-grade lamp end caps, robust UV quartz sleeve mounts) is designed for integration into systems that operate continuously at elevated flow rates and pressures, without the performance degradation that occurs when commercial-grade UV units are over-specified into industrial duty cycles.
Alpha UV's dealer supply model includes the full documentation package required for the dealer's downstream industrial client commissioning: UV dose calculation certificate for the rated flow, Philips TUV lamp COA, SS304 material test certificate, compliance statement compatible with IATF 16949 and ISO 14001 supplier documentation requirements, and CPCB Class A effluent reuse compliance statement for ETP application customers. IGST-compliant inter-state supply invoice documentation (Uttar Pradesh to Maharashtra) was completed accurately, supporting the dealer's GST credit claim and procurement compliance records.
Alpha UV's manufacturer support is available to the dealer's downstream clients throughout the system warranty period — IIT Patna-trained engineers can respond to technical queries from industrial end users, generate site-specific UV dose calculation reports if requested at IATF or ISO audits, and support commissioning documentation for major industrial accounts.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Total Coliform (industrial process water) | 240 CFU/100 mL (application-specific) | Not detected | IATF process input / CPCB Class A: 0 |
| E. coli | 45 CFU/100 mL | Not detected | CPCB Class A: 0 CFU/100 mL |
| Fecal Coliform (ETP effluent reuse) | 3,200 MPN/100 mL | < 50 MPN/100 mL | CPCB Class A: < 100 MPN/100 mL |
"The 4-inch flange format, the IGST documentation, and the Philips COA were all correct on delivery. For industrial OEM supply into IATF-audited facilities, that level of accuracy makes the difference."
— Procurement Manager, Industrial Water Treatment Dealer, Aurangabad
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Industrial UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →