A wellness and personal care product manufacturer in Palghar, Maharashtra deployed Alpha UV's ALPHA-406C UV conveyor system for GMP-compliant surface sterilization of products and packaging on the production line, eliminating chemical contact and production stoppages.
Project at a glance
ALPHA-406C UV conveyor surface sterilization system, continuous in-line operation, chemical-free, GMP Schedule M 2025 and FSSAI surface sterility compliance — Palghar, Maharashtra personal care manufacturing facility.
The Challenge
Maharashtra's personal care and wellness manufacturing sector has expanded significantly under the government's PLI scheme for pharmaceuticals and medical devices, with a cluster of facilities in the Palghar, Thane, and Raigad belt supplying national and international FMCG brands. Personal care product manufacturers — producing skincare, haircare, and wellness supplements — are subject to GMP (Good Manufacturing Practice) requirements under Schedule M 2025, which mandates documented surface sterility for product-contact materials, packaging, and manufacturing equipment in contact with formulations. Updated Schedule M 2025 provisions have sharpened the documentation requirements for surface sterilization, creating compliance pressure on manufacturers whose current processes rely on wet chemical methods.
Wet chemical sterilization of product and packaging surfaces — typically using isopropyl alcohol sprays, hydrogen peroxide wipes, or UV tunnels with chemical augmentation — introduces multiple operational complications in a personal care manufacturing context. Chemical residues on packaging surfaces can migrate into product formulations, affecting stability testing outcomes and ingredient claims. Drying time after chemical application reduces throughput and creates scheduling gaps in continuous production lines. Chemical handling, storage, and waste disposal requirements add EHS compliance overhead and generate documentation obligations under Maharashtra's hazardous waste management rules. For facilities producing products for export markets that test for chemical residues, any detectable sanitiser carryover creates rejection risk.
The Palghar facility produces both cosmetic and over-the-counter wellness products on the same production line — a configuration that requires a sterilization method flexible enough to handle different product types and packaging formats without chemical reformulation. The plant manager required a surface sterilization system capable of continuous in-line operation at full production line speed, without chemical contact, without production stoppages, and with GMP-auditable documentation.
The Solution
Alpha UV supplied and installed the ALPHA-406C UV conveyor system — a purpose-built surface UV sterilization unit designed for continuous in-line operation on manufacturing conveyors. Alpha UV's IIT Patna-trained engineers sized the ALPHA-406C's UV exposure zone to the Palghar facility's conveyor line speed, confirming that at the production line's maximum throughput rate, every product and packaging unit passing through the UV exposure zone receives the target surface UV dose (minimum 20 mJ/cm² for surface pathogen inactivation on smooth packaging materials).
The ALPHA-406C projects high-intensity UV-C light (254nm germicidal wavelength) across the full conveyor width through a precisely engineered UV irradiation chamber that maximises dose uniformity across the surface. The system uses high-output UV-C lamps configured for even irradiation — no shadowed zones, no dose variation across the conveyor width — ensuring that both the top surface and, where applicable, exposed side surfaces of products and packaging receive the validated dose in a single conveyor pass. No chemical contact, no drying time, no production stoppage — the system operates continuously as an in-line sterilization stage.
The ALPHA-406C's design complies with Schedule M 2025 GMP requirements for UV surface sterilization equipment: the UV exposure chamber is constructed from materials compatible with pharmaceutical and food-grade manufacturing environments, the UV intensity output is monitored continuously by an integrated sensor, and the system generates a time-stamped UV dose log that serves as the GMP-auditable surface sterilization record. FSSAI inspection documentation is supported by the UV dose log and the system's calibration certificate.
Alpha UV delivered a complete GMP documentation package at installation: UV surface dose validation report (measuring dose uniformity across the conveyor width at the rated line speed), Schedule M 2025 compliance statement, FSSAI surface sterilization compliance confirmation, UV intensity calibration certificate, and a preventive maintenance schedule for the facility's GMP equipment file. The UV dose validation was conducted by Alpha UV's engineering team using a calibrated UV radiometer across the full conveyor width to confirm dose uniformity.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Surface E. coli (packaging) | 12 CFU/cm² (control surface) | Not detected (< 1 CFU/cm²) | GMP Schedule M 2025: 0 CFU/cm² |
| Surface Mould/Yeast | 8 CFU/cm² | Not detected | GMP: 0 CFU/cm² |
| Chemical sanitiser residue (product surface) | Detected (from prior IPA spray) | 0 (no chemical applied) | Export market: chemical-free |
| Production downtime (sterilization) | 15 min/hr (chemical spray+dry) | 0 min (continuous in-line UV) | Target: continuous production |
"GMP audit came within two months of installation. The UV surface dose records and the Schedule M 2025 compliance statement were exactly what the inspector needed — no chemical use, no drying time, complete documentation."
— Quality Assurance Manager, Personal Care Manufacturer, Palghar
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Industrial UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →