An industrial R&D facility in Peenya, Bangalore running ozone-UV advanced oxidation process (AOP) research required a 185/254nm dual-wavelength SS316L UV system at 200 mJ/cm² for RO membrane testing — installed with SCADA 4-20mA output for research data integration.
Project at a glance
SS316L dual-wavelength 185/254nm AOP UV system, 200 mJ/cm², 2,000 LPH, SCADA 4-20mA output — Peenya, Bangalore industrial R&D facility, ozone-UV advanced oxidation for RO membrane performance testing.
The Challenge
Bangalore's Peenya Industrial Area is one of India's largest and oldest industrial estates, housing a significant concentration of engineering, electronics, and water technology R&D facilities alongside manufacturing units. Industrial water technology R&D in India — particularly research into advanced water treatment processes for pharmaceutical, semiconductor, and high-purity industrial applications — has expanded with government investment in CSIR, DST, and industry-funded research programmes. Facilities conducting advanced oxidation process (AOP) research require UV systems that go significantly beyond standard germicidal UV water disinfection specifications, with dose levels, wavelength configurations, and monitoring outputs suited to research rather than production use.
AOP systems combine UV irradiation with ozone or hydrogen peroxide to generate hydroxyl radicals (OH•) — the most powerful oxidising species available in water treatment chemistry. In a UV-ozone AOP system, UV photons at 185nm photolyse dissolved ozone molecules to produce OH• radicals, while UV photons at 254nm simultaneously provide direct germicidal inactivation. This dual-wavelength photolysis mechanism requires a UV system capable of generating significant 185nm output — a wavelength that standard germicidal UV lamps produce only in trace quantities. Research-grade AOP UV systems require specific lamp types (low-pressure lamps without the ozone-blocking doped quartz of standard germicidal lamps) and high UV dose levels (100–300 mJ/cm²) to generate the hydroxyl radical concentrations required for meaningful AOP research data.
RO membrane performance testing — evaluating membrane resistance to fouling, chemical degradation, or enhanced permeability under AOP pretreatment — requires a water matrix that is precisely characterised and reproducible between test runs. Any variation in UV dose output, ozone photolysis efficiency, or microbial loading of the feed water introduces uncontrolled variables that invalidate test comparisons between membrane types or operating conditions. The Peenya R&D facility required a UV system with SCADA integration (4-20mA UV intensity signal output) to log real-time dose data for every test run — a critical research data quality requirement not met by standard commercial UV systems.
The Solution
Alpha UV's IIT Patna-trained engineers designed and supplied an SS316L AOP UV system at 2,000 LPH configured specifically for the Peenya R&D facility's advanced oxidation research application. The system specification was developed in consultation with the facility's research team, reviewing the AOP research protocol, test water flow requirements, ozone dose parameters, and SCADA data integration requirements.
The AOP UV system uses dual-wavelength low-pressure UV-C lamps generating both 185nm and 254nm output — the 185nm component provides the photon energy required for direct ozone photolysis and hydroxyl radical generation, while the 254nm component provides direct germicidal inactivation of any residual microorganisms in the test water matrix. At 2,000 LPH flow with the facility's deionised water feed (UVT 99%), the system delivers a validated UV dose of 200 mJ/cm² — 8× the standard drinking water disinfection dose — providing the high photon flux required for effective ozone photolysis at the facility's target OH• generation rates.
SS316L electropolished construction was specified for the Alpha UV SS316L AOP UV System, 2,000 LPH for two reasons: first, SS316L's higher molybdenum content provides superior resistance to the trace ozone concentrations in the AOP process water that would cause pitting corrosion in SS304 chambers; second, the electropolished surface finish eliminates surface roughness that could cause non-uniform ozone decomposition or localised radical quenching at the chamber wall, ensuring the UV dose and radical generation data recorded by the SCADA system accurately reflects the bulk water treatment rather than surface artefacts.
The SCADA 4-20mA UV intensity output from the integrated calibrated UV sensor transmits real-time dose data to the facility's research data acquisition system, generating a time-stamped UV dose log for every test run. This output enables the research team to calculate precise CT values (UV dose × contact time) for each experimental condition and cross-reference UV dose data with membrane performance metrics — a capability that is essential for publishing reproducible research data and comparing results across test runs separated by weeks or months.
Alpha UV delivered a complete R&D documentation package at commissioning: AOP UV system design report (covering 185/254nm dual-wavelength output characterisation, ozone photolysis efficiency at the rated dose, and OH• radical yield estimate), UV dose validation report using calibrated radiometry at multiple flow rates, SS316L material test certificate, SCADA 4-20mA output calibration record, and an O&M manual referencing the research facility's specific operating protocol.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| UV Dose (AOP system) | 60 mJ/cm² (prior single-wavelength system) | 200 mJ/cm² (Alpha UV SS316L AOP UV System) | Research AOP: 100–300 mJ/cm² |
| OH• radical generation (relative) | Low (insufficient 185nm output) | High (dual-wavelength 185nm photolysis) | AOP research: maximum yield |
| RO test water microbial count | 12 CFU/mL (periodic contamination events) | < 1 CFU/mL (continuous) | Research water: < 1 CFU/mL |
| SCADA dose data availability | None (manual measurement only) | Continuous 4-20mA real-time log | Research protocol: continuous data |
| Test run reproducibility (UV dose CV%) | ±18% (prior system, no SCADA) | ±2% (SCADA-monitored continuous dose) | Research: ±5% maximum CV |
"Our AOP research protocol requires consistent UV dose and real-time dose logging for every test run. The 185/254nm dual-wavelength system with SCADA 4-20mA output gave us both — test reproducibility went from ±18% to ±2%."
— Research Engineer, Industrial R&D Facility, Peenya, Bangalore
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Industrial UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →