An EPC water treatment company in Aligarh, Uttar Pradesh incorporated an Alpha UV sterilizer unit into a water purification project, leveraging full manufacturer documentation for client commissioning and handover.
Project at a glance
Alpha UV sterilizer unit with UV dose calculation report and compliance documentation supplied to an EPC water treatment contractor in Aligarh, UP — terminal disinfection stage for a water purification project.
The Challenge
Uttar Pradesh's EPC water treatment sector is one of India's most active, driven by Jal Jeevan Mission household water connection projects, industrial water supply schemes under UPSIDA, and institutional water treatment tenders from hospitals, colleges, and municipal bodies. EPC water treatment companies operating in Aligarh — Uttar Pradesh's precision manufacturing and industrial hub — supply water purification systems to a diverse client base including automotive component manufacturers, textile and lock-making industries, educational institutions, and municipal bodies. These clients have varying regulatory frameworks, but all require the EPC contractor to demonstrate that the terminal disinfection stage meets the relevant standard — BIS IS 10500 for potable water, CPCB Class A for recycled water, or facility-specific requirements.
UV system reliability is a post-handover reputation issue for EPC contractors: a system that underperforms, fails within the warranty period, or lacks documentation creates warranty claims and site revisits that the contractor must absorb. EPC contractors in UP have experienced repeated issues with UV units from unverified manufacturers — systems that arrive without data sheets, have no traceable lamp specifications, and cannot provide a UV dose calculation report when the end client requests one at their own inspection or audit. These documentation gaps become the EPC contractor's problem after handover.
The Aligarh EPC contractor required a UV sterilizer from a manufacturer with verifiable credentials — IIT-trained engineering team, documented UV dose ratings, Philips lamp supply chain, and the capacity to generate site-specific UV dose calculation reports if required by end clients. The contractor needed to be able to present manufacturer-backed compliance credentials to their own clients rather than sourcing a UV unit from a commodity supplier whose product quality and documentation cannot be verified.
The Solution
Alpha UV supplied one UV sterilizer unit to the Aligarh EPC contractor for integration as the terminal disinfection stage in their water purification system project. Alpha UV's IIT Patna-trained engineers confirmed the UV system's dose rating against the contractor's specified flow and water quality parameters, providing a UV dose calculation report that the contractor could present to their end client as manufacturer-validated performance evidence.
The Alpha UV sterilizer unit delivers a validated minimum germicidal UV dose at the specified application flow, achieving greater than 4-log coliform reduction at the terminal point of the purification system. The unit is sized and specified for the application rather than being a generic catalogue selection — Alpha UV's engineering team reviewed the contractor's project specifications before confirming the model and generating the documentation.
Alpha UV's UV disinfection systems are backed by full manufacturer technical support — IIT Patna-trained engineers are available to support commissioning queries, respond to end-client technical questions, and generate additional site-specific documentation if requested during the project guarantee period. This reduces the EPC contractor's risk exposure during the warranty phase: when an end client asks a technical question about the UV system, the contractor can direct the query to the manufacturer rather than attempting to answer from incomplete supplier data.
The complete documentation package supplied at delivery included the UV dose calculation report, product data sheet with technical specifications, Philips TUV lamp COA (where applicable), compliance statement for the applicable standard (BIS IS 10500 or as required), and HSN classification documentation for the contractor's GST and procurement records.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Total Coliform (purification system outlet) | 120 CFU/100 mL (pre-UV) | Not detected | BIS IS 10500: 0 CFU/100 mL |
| E. coli | 18 CFU/100 mL | Not detected | BIS IS 10500: 0 CFU/100 mL |
| UV Dose Delivered | N/A (no prior UV) | ≥ 40 mJ/cm² | WHO: ≥ 25 mJ/cm² |
"When the client asked for a UV dose calculation at their site inspection, Alpha UV had it ready within hours. That is the kind of technical depth that makes a difference in EPC project handovers."
— Project Director, Water Treatment EPC Company, Uttar Pradesh
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore UV Disinfection for STP/ETP Plants
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →