A commercial brewery at Kotputli near Jaipur required a Tri-Clamp SS304 UV system for chloramine removal and process water disinfection at 15,000 LPH — installed with Philips 75W TUV lamps at 60 mJ/cm² for FSSAI brewery compliance.
Project at a glance
15,000 LPH SS304 Tri-Clamp UV system, 3 × Philips 75W TUV, 60 mJ/cm² at 76mm Tri-Clamp, chloramine removal + microbial disinfection — Kotputli, Jaipur commercial brewery, FSSAI brewery compliant, without PLC.
The Challenge
Rajasthan's brewing industry has expanded rapidly with the state's liberalised brewery licensing reforms, with a cluster of commercial production units emerging in the Jaipur-Kotputli corridor supplying Rajasthan's hotel, restaurant, and organised retail alcohol market. Commercial breweries in India are licensed by the state Excise Department and are simultaneously subject to FSSAI food safety standards for all process inputs including water — meaning brewery quality teams face a dual compliance obligation. FSSAI brewery guidelines classify process water as a Critical Control Point requiring documented microbial safety and, where municipal water is used, documented chloramine removal to protect yeast activity.
Municipal water supplied to Kotputli's industrial zone contains chloramines at concentrations of 0.3–0.8 mg/L — a range sufficient to inhibit yeast flocculation, reduce fermentation efficiency, and generate chlorophenol off-flavours in finished beer. Breweries in Rajasthan's dry, high-temperature climate also face elevated risks of water-borne contamination through distribution network ingress during summer months when water pressure fluctuates — a risk that standard municipal supply without terminal disinfection cannot address. The Kotputli brewery's water treatment train (sand filtration + carbon filtration) was adequate for turbidity and chlorine but could not reliably remove chloramines or provide a documented microbial kill step.
The brewery's Tri-Clamp pipework — standard for Indian commercial brewing CIP systems — required a UV system with matching connection format; threaded or flanged connections would require adapters that introduce dead zones and CIP complexity. The plant engineer required a simple, robust system without PLC complexity — brewery operatives are trained for brewing process management, not programmable controller maintenance.
The Solution
Alpha UV's IIT Patna-trained engineers sized an SS304 Tri-Clamp UV system at 15,000 LPH for the brewery's water treatment line at 15,000 LPH — covering the brewing process water inlet and CIP rinse circuit simultaneously. At this flow rate, the system must deliver 60 mJ/cm² to achieve the photolysis threshold for monochloramine N-Cl bond cleavage, requiring 3 × Philips 75W TUV UV-C lamps in the chamber configuration.
The UV system is configured with 3 × low-pressure mercury UV-C lamps in a 76mm Tri-Clamp SS304 stainless steel chamber — a direct fit for the brewery's existing Tri-Clamp process pipework. At 60 mJ/cm² UV dose, the system achieves both chloramine photolysis (N-Cl bond cleavage, eliminating monochloramine and dichloramine) and 4-log microbial inactivation of E. coli and wild yeast strains that could contaminate fermentation vessels. The dual function — chloramine removal plus microbial kill — in a single UV pass eliminates the need for separate treatment stages.
The system operates without a PLC — a simple on/off switch with a UV intensity indicator lamp and a low-intensity audible alarm. This configuration was specifically selected for the brewery environment: simple enough for brewing operatives to operate, reliable enough to run continuously through production cycles, and maintainable by a standard engineering team without controller programming knowledge. The low-intensity alarm is calibrated at 85% of rated UV output — providing advance warning before chloramine breakthrough or dose shortfall affects the brewery's FSSAI CCP record.
Alpha UV delivered a complete FSSAI brewery compliance package at commissioning: UV dose calculation report validating chloramine photolysis at 60 mJ/cm², Philips TUV lamp COA, SS304 Tri-Clamp hygienic design compliance statement, FSSAI brewery process water CCP protocol, and a lamp replacement schedule. The CCP protocol defines the UV intensity alarm as the critical limit trigger — a format directly usable by the brewery's quality team at FSSAI brewery HACCP audits.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Monochloramine (NH2Cl) | 0.5 mg/L | < 0.02 mg/L | Brewery water: < 0.1 mg/L |
| Total Chloramine (combined) | 0.7 mg/L | < 0.03 mg/L | FSSAI brewery: 0 chloramine carryover |
| Wild Yeast Contamination | Detected (batch testing) | Not detected | Brewery QC: 0 |
| Total Coliform | 28 CFU/100 mL | Not detected | FSSAI: 0 CFU/100 mL |
| Chlorophenol off-flavour | Detected (tasting panel) | Not detected | Internal brewery QC: 0 |
"Chloramine off-flavours were costing us batch rejections. The 60 mJ/cm² Tri-Clamp system eliminated them completely — FSSAI auditor accepted the UV sensor log as the CCP record."
— Brewery Engineer, Commercial Brewery, Rajasthan
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Brewery UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageRelated Reading
Brewery UV Water Treatment — Chloramine Removal Case Study
Deep-dive technical article on this application from our engineering team.
Read the articleMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →