Alpha UV supplied a 27,000 LPH UV system with integrated control panel for a premium residential complex in Sector 150, Noida, UP — BIS IS 10500 potable water compliance and 12-month manufacturer warranty for RERA developer handover.
Project at a glance
27,000 LPH UV system with integrated control panel, Philips TUV UV-C, SS304, 40 mJ/cm², BIS IS 10500 potable water compliance, 12-month manufacturer warranty — Sector 150, Noida premium residential complex, RERA handover package.
The Challenge
Noida's Sector 150 is one of Delhi NCR's most prominent premium residential development zones, characterised by large-format high-rise townships offering sports and wellness amenities targeting mid-to-upper HNI buyers. RERA (Real Estate Regulation and Development Act) registration under UPRERA mandates that developers provide documented evidence of potable water supply meeting BIS IS 10500 standards as part of the statutory project handover package delivered to buyers at possession. UPRERA enforcement has tightened significantly — developers who fail to provide water quality documentation at handover face complaints that can result in UPRERA orders, compensation awards, and project reputation damage in a highly competitive market.
Municipal water supply in Noida's sector 150 zone — served by Greater Noida Industrial Development Authority (GNIDA) infrastructure — provides treated water that may still contain residual microbial contamination at distribution endpoints due to network leakage and pressure fluctuations common in rapidly expanding township zones. BIS IS 10500:2012 specifies a maximum coliform count of zero CFU/100 mL — a standard that cannot be reliably met without validated terminal disinfection at the residential complex water distribution header. High-rise residential complexes distribute water through extensive internal pipework — often 10–20 floors — where recontamination after centrally treated supply can occur at any break or join in the internal distribution network.
The Sector 150 developer required a UV system with a control panel suitable for operation by residential complex facility management staff — typically not water treatment specialists — with fault indication clear enough to prompt timely maintenance action without technical expertise. The 12-month warranty was a specific procurement requirement: the developer's buyer possession period extends over 12 months from the first handover, and buyers who discover water quality issues during the first year expect the developer to have backed the water treatment equipment with a warranty period covering this critical phase.
The Solution
Alpha UV's IIT Patna-trained engineers sized the ALPHA-R304-27K UV system at 27,000 LPH for the Sector 150 complex's domestic water demand profile — calculated from the complex's occupancy design load, domestic hot and cold water demand, and irrigation/amenity water circuits. The 27,000 LPH capacity was confirmed with a 20% hydraulic safety margin to prevent dose shortfall during peak morning draw periods in a high-occupancy residential complex.
The ALPHA-R304-27K is configured with Philips TUV UV-C lamps in a compact SS304 stainless steel chamber, delivering a minimum UV dose of 40 mJ/cm² at the rated 27,000 LPH flow with the feed water UVT of 95% typical of GNIDA municipal supply. At 40 mJ/cm², the system achieves greater than 4-log E. coli and total coliform reduction — the standard required to deliver BIS IS 10500 potable water at the complex's distribution outlets. Philips TUV UV-C lamps provide certified, stable UV output across the lamp's 12,000-hour rated life — consistent performance across the full 12-month warranty period without dose degradation.
The integrated control panel includes a UV intensity display showing real-time operating dose, an audible and visual lamp fault alarm routed to the complex's building management system (BMS) or facility management station, and a digital hour meter for maintenance scheduling. This panel enables facility management staff to verify the UV system's operational status during routine rounds without technical training — the lamp fault alarm provides unambiguous notification requiring a maintenance call. The BMS integration option allows the developer's facility management contractor to monitor the UV system status remotely.
Alpha UV's 12-month manufacturer warranty covers the UV system's reactor, control panel, UV lamp performance, and quartz sleeve integrity — the components that determine whether the system maintains its rated dose output throughout the warranty period. Alpha UV's service team is available for warranty call-outs within the warranty period, providing the developer with a defensible response if any buyer raises water quality concerns at UPRERA.
A complete RERA and BIS IS 10500 handover documentation package was delivered at commissioning: UV dose calculation report, Philips TUV lamp COA, SS304 material certificate, BIS IS 10500 potable water compliance statement, UV system commissioning test record, 12-month warranty certificate, and an O&M manual formatted for residential complex facility management teams.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Total Coliform (distribution outlet) | 28 CFU/100 mL (GNIDA supply at complex entry) | Not detected | BIS IS 10500: 0 CFU/100 mL |
| E. coli | 5 CFU/100 mL | Not detected | BIS IS 10500: 0 CFU/100 mL |
| UV Dose Delivered | N/A (no prior UV) | 40 mJ/cm² | WHO: ≥ 25 mJ/cm² |
| Turbidity | 0.4 NTU | 0.4 NTU (unchanged) | BIS IS 10500: ≤ 1 NTU |
"We wanted to give homebuyers a water quality guarantee they could verify. The 12-month warranty and BIS IS 10500 documentation package satisfied the UPRERA requirements and our buyers' water quality questions on possession day."
— Project Director, Residential Developer, Uttar Pradesh
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Commercial & Residential UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies
Mon–Sat · 9 AM–6 PM IST · IIT Patna alumni on call
IIT Patna-engineered. Philips UV-C powered. Tell us your application and we'll respond within 2 hours.
+91 93183 05878
Get Quote →
Call Direct
+91 95995 00580
Tap to Call →
Send Enquiry
Detailed specifications form
Open Form →