A heritage hotel in the pilgrim city of Bodhgaya, Bihar required a validated UV disinfection system for guest drinking and service water — installed with SS316L polished construction, UV intensity alarm panel, and BIS IS 10500 documentation for international brand audit compliance.
Project at a glance
10,000 LPH SS316L polished UV water disinfection system, 2 × Philips 75W TUV, 40 mJ/cm², with control panel and UV intensity alarm — Bodhgaya heritage hotel, BIS IS 10500 and international brand audit compliant.
The Challenge
India's hospitality sector serves a large and growing international tourist and pilgrim population, with Bodhgaya — one of Buddhism's most sacred pilgrimage sites — receiving over 500,000 visitors annually including significant numbers from East Asia, Southeast Asia, Europe, and the Americas. Premium hospitality properties in Bodhgaya maintain international brand standards that mandate water safety documentation comparable to global hotel standards — a requirement enforced through periodic brand audits by international hotel management companies and certification bodies. Bihar's water quality challenges are well-documented: groundwater in the Gaya district has historically shown elevated arsenic concentrations alongside bacterial contamination, and municipal supply in Bodhgaya's pilgrimage zone experiences pressure and quality fluctuations during peak pilgrimage seasons (Purnima, Vaisakhi) when the town's population surges significantly.
International guests at five-star pilgrim destination hotels represent a vulnerable population from a water safety perspective: unacclimated to South Asian water pathogens, frequently travelling with health-conscious expectations, and in some cases elderly or immunosuppressed. A waterborne illness incident at a Bodhgaya heritage hotel reaches international travel advisory networks rapidly, with severe consequences for the property's international booking channels and brand affiliation. Hotels in this segment cannot rely on a single municipal supply filtration system — they require a validated terminal disinfection stage with traceable performance documentation that satisfies both FSSAI food safety requirements and international brand audit standards.
The hotel's existing water treatment system — sand filtration plus a chlorination dosing system — provided basic treatment but did not meet the brand auditor's requirements for a documented terminal disinfection CCP with UV intensity monitoring. The chlorination dosing system was also generating chlorine taste complaints from international guests accustomed to European and East Asian water standards. A UV-based terminal disinfection upgrade with BIS IS 10500 documentation and UV intensity alarm was required ahead of the annual international brand audit.
The Solution
Alpha UV's IIT Patna-trained engineers conducted a site assessment at Bodhgaya, reviewing the hotel's water demand profile across guest rooms, restaurant service, kitchen, and pool circuits. The engineering team sized the replacement system at 10,000 LPH — covering the hotel's peak domestic water demand across all service areas — with a 25% hydraulic safety margin for peak pilgrimage season occupancy surges.
Alpha UV installed an SS316L polished UV disinfection system at 10,000 LPH — an SS316L polished stainless steel chamber (selected for its superior corrosion resistance in high-humidity hospitality environments and aesthetic compatibility with premium hotel plant room standards) fitted with 2 × Philips 75W TUV UV-C lamps at the germicidal 254nm wavelength. The system delivers a validated minimum UV dose of 40 mJ/cm² at the rated 10,000 LPH flow — well above the WHO recommended 25 mJ/cm² minimum. The control panel includes a continuous UV intensity monitoring display and an audible+visual alarm that alerts engineering staff if intensity drops below the minimum threshold, providing the monitored CCP documentation record that international brand auditors require.
SS316L polished construction was specifically selected over SS304 for the Bodhgaya installation: the higher molybdenum content in SS316L provides superior resistance to the pitting corrosion that can develop in humid, high-temperature hotel plant rooms, and the polished finish is specified by premium hotel brand standards for water contact equipment in potable water supply systems. Alpha UV's UV intensity alarm is routed to the hotel's maintenance management system, ensuring that engineering staff are notified immediately on any dose shortfall without manual monitoring rounds.
The chlorination dosing system was retained as a secondary barrier at reduced dose (0.2 mg/L residual) for distribution system protection — standard practice in Indian premium hotel water safety management. Alpha UV's UV system handles the terminal microbial kill, while the low residual chlorine protects against post-treatment recontamination in the distribution piping.
Alpha UV delivered a complete international brand audit and BIS IS 10500 documentation package at commissioning: UV dose calculation report, Philips 75W TUV lamp COA, SS316L material test certificate, UV intensity alarm calibration record, BIS IS 10500 potable water compliance statement, and an O&M manual formatted for the hotel's engineering department. The documentation package was reviewed by Alpha UV's engineering team to confirm compatibility with the hotel's international brand audit checklist before delivery.
Technical Details
Results
Before / After
| Parameter | Before UV Treatment | After UV Treatment | Regulatory Standard |
|---|---|---|---|
| Total Coliform (guest water) | 18 CFU/100 mL | Not detected | BIS IS 10500: 0 CFU/100 mL |
| E. coli | 4 CFU/100 mL | Not detected | BIS IS 10500: 0 CFU/100 mL |
| Chlorine taste (threshold) | Detected (guest complaints) | Below detection (UV replaces chlorination as primary kill) | Hotel guest satisfaction: none |
| UV Dose Delivered | N/A (no prior UV) | 40 mJ/cm² | WHO: ≥ 25 mJ/cm² |
| Turbidity | 0.3 NTU | 0.3 NTU (unchanged) | BIS IS 10500: ≤ 1 NTU |
"Our international brand audit requires traceable UV documentation and monitored CCP evidence. Alpha UV supplied the Philips COA, SS316L cert, and UV intensity alarm record — the auditor cleared the water system in minutes."
— Chief Engineer, Heritage Hotel, Bodhgaya, Bihar
Next Steps
Similar application?
Get a quote in 24 hours. Tell us your flow rate, application, and location.
Get a Quote on WhatsAppExplore Hospital & Hospitality UV Disinfection Systems
Technical specifications, UV dose data, compliance standards, and product options for this application.
View Application PageMore Case Studies